Exercises with automatic assessment
31 graded exercises with automatic assessment
Each exercise is checked by operating your circuit like an instructor would: any correct solution passes, and failed checks explain what was observed.

Pneumatics
- Direct control of a single-acting cylinder — Build a circuit in which a single-acting cylinder extends while the push button valve S1 is held, and retracts by its spring as soon as S1 is released.
- Direct control of a double-acting cylinder — A double-acting cylinder must extend while S1 is held and retract when it is released. Both chambers must be driven by air — no spring.
- Indirect control with memory — A short press on S1 extends the double-acting cylinder and it stays extended. A short press on S2 retracts it and it stays retracted. (S1 is the left push button, S2 the …
- OR function: two places to start — A single-acting cylinder must extend while S1 or S2 (or both) is held — for example a machine that can be operated from two sides.
- AND function: two-hand safety — For safety the single-acting cylinder may only extend while S1 and S2 are both held. One button alone must not move it.
- Speed control: slow extension, fast return — With a selector switch valve the double-acting cylinder extends (switch on) and retracts (switch off). The extension must take between 2 and 8 seconds; the return must be…
- Automatic return with a roller lever valve — A short press on S1 starts one cycle: the double-acting cylinder extends and returns automatically when it reaches the front end position. It must then stay retracted unt…
- Continuous cycle with a selector switch — While the selector switch is on, the double-acting cylinder moves back and forth continuously. When it is switched off, the cylinder finishes its cycle and stops retracte…
- Timed return (pneumatic timer) — A short press on S1 extends the double-acting cylinder. At the front end position it must wait at least 1 second and then return by itself.
Electropneumatics
- Direct electrical control — Push button S2 of the electrical push-button module controls a solenoid valve: the double-acting cylinder extends while S2 is held and retracts when it is released.
- Self-holding relay: start and stop — A short press on S2 (start) extends the cylinder and it stays extended. A short press on S3 (stop) retracts it. Use a relay with a self-holding contact; stop must win if …
- Automatic return with a proximity sensor — A short press on S2 extends the double-acting cylinder; a magnetic proximity sensor at the front end position makes it return automatically. It then stays retracted.
- Timed return with a time relay — A short press on S2 extends the cylinder. When it reaches the front end position it must wait about 2 seconds (at least 1.5 s) and then return automatically.
- Position indicator lamp — The cylinder is controlled by S2 (extends while held). Indicator lamp H1 must be on only while the cylinder is fully extended.
- Blinking signal with time relays — While the detented switch S1 is on, indicator lamp H1 must blink: about 1 s on, 1 s off (each phase between 0.5 s and 2 s). When S1 is switched off, H1 goes off.
Blocking signals (signal overlap)
- Blocking signals: idle return rollers (A+ B+ B− A−) — One press of S runs A+ B+ B− A− once. Wired directly, this circuit blocks twice: at rest b0 holds pilot 12 of the valve of A, so S cannot start A+; after B+ a1 still hold…
- Blocking signals: signal shortening with time delay valves — The same task, A+ B+ B− A− once per press of S, with ordinary roller lever valves this time. Remove the two blocking signals (b0 on the valve of A, a1 on the valve of B) …
- Find the blocking signal: A+ A− B+ B− — One press of S runs A+ A− B+ B− once. Draw the displacement-step diagram, find the blocking signal of the direct circuit (S → A+, a1 → A−, a0 → B+, b1 → B−) and remove it…
- Four blocking signals: A+ B+ C+ C− B− A− — Three double-acting cylinders A, B, C (left to right), all retracted at rest. One press of S runs A+ B+ C+ C− B− A−. With direct roller signals this sequence has four blo…
- Electrical blocking signals: A+ B+ B− A− with a group relay — Cylinders A and B with 5/2 double solenoid (impulse) valves and proximity sensors. One press of S2 runs A+ B+ B− A− once. Wired directly (S2 → Y1 of A, a1 → Y1 of B, b1 →…
- Find the electrical blocking signal: A+ A− B+ B− — Cylinders A and B with 5/2 double solenoid (impulse) valves and proximity sensors. One press of S2 runs A+ A− B+ B− once. Wired directly (S2 → A+, a1 → A−, a0 → B+, b1 → …
Sequences, cascades and stepping chains
- Sequence A+ B+ A− B− (direct signals) — Two double-acting cylinders A (left) and B (right). One press on the start button S runs the sequence A+ B+ A− B− once. Use roller lever valves as end-position signals (a…
- Sequence A+ B+ B− A− with a 2-group cascade — Start button S runs A+ B+ B− A− once. With direct roller signals this sequence blocks (signal overlap at the 5/2 valve of B). Solve it with a cascade: a group valve switc…
- Sequence A+ A− B+ B− with a 3-group cascade — Start button S runs A+ A− B+ B− once. Both cylinders change direction twice, so the signals overlap twice: build a 3-group cascade (GR.1 A+, GR.2 A− B+, GR.3 B−) with two…
- Quickstepper: A+ B+ B− A− — Use the Quickstepper (pneumatic sequencer) to run A+ B+ B− A− once per press of S. Each step drives one valve pilot; each transition condition is a roller valve.
- Stepper modules (TAA / TAB): A+ B+ B− A− — Build a stepping chain with stepper modules: one initial step module TAB and four step modules TAA. One press of S runs A+ B+ B− A−. Each module is set by the previous st…
- Electropneumatic sequence A+ B+ A− B− — Cylinders A and B with 5/2 double solenoid valves and magnetic proximity sensors at both end positions. A press of S2 runs A+ B+ A− B− once.
- Electrical stepping chain: A+ B+ B− A− — Build an electrical stepping chain with relays for A+ B+ B− A− (one cycle per press of S2). Each step relay latches itself, is set by the previous step AND its sensor, an…
- Pneumatic stepping chain: A+ A− B+ B− — Solve A+ A− B+ B− (one cycle per press of S) with a pneumatic stepping chain: one block per step, each made of a memory valve (impulse valve) and a two-pressure valve (AN…
- Three cylinders: C+ A− B+ B− A+ C− — Three double-acting cylinders A, B, C (left to right). At rest A is extended, B and C are retracted. One press of S runs C+ A− B+ B− A+ C−. Any method is accepted: a 6-bl…
- Quickstepper: C+ A− B+ B− A+ C− — The same machine (A extended at rest, B and C retracted): run C+ A− B+ B− A+ C− once per press of S, this time with the Quickstepper. Its six steps match the six movement…

Build your first circuit in two minutes — free, in the browser.Open the 3D workbenchPlans and pricing