Open the 3D workbench

Component library

178 simulated components

Every component has a 3D model on the workbench and an ISO 1219 / EN 61082 symbol in the live circuit diagram.

Pneumatics

ComponentFunction
Service unit with main line (workstation)On-off valve with filter regulator module (540691) of the workstation: fed directly by the compressor hose, 5 µm filter, gauge, regulated 0.5–7 bar
Compressed air supplyLab air outlet with ball valve
Air service unitFilter regulator with gauge and 3/2 on-off valve (MS4)
Manifold (8 outlets)Distributor block with 8 self-sealing push-in connectors; QS-8 inlet at one end, QS-8 through-outlet at the other for the 8 mm main line of a valve terminal.
Manifold (12 outlets)Distributor block with 12 self-sealing push-in connectors; QS-8 inlet at one end, QS-8 through-outlet at the other for the 8 mm main line of a valve terminal.
Manifold (16 outlets)Distributor block with 16 self-sealing push-in connectors; QS-8 inlet at one end, QS-8 through-outlet at the other for the 8 mm main line of a valve terminal.
T-connectorQST T-connector to branch a pneumatic line.
Single-acting cylinderESNU-20-50: spring return, 50 mm stroke
Double-acting cylinderRound cylinder DSNU-20-100 with magnetic piston and switching cam on the rod, 100 mm stroke
3/2-way valve with push button, normally closed (NC)Push-button actuated, spring return
3/2-way valve with selector switchDetented switch: click to toggle.
5/2-way valve with selector switchDetented in both positions.
3/2-way roller lever valve, normally closed (NC)Limit valve
3/2-way valve, pneumatic, normally closed (NC)Pneumatically actuated by pilot 12, spring return.
5/2-way valve, pneumaticMonostable: pilot 14, spring return.
5/2-way impulse valve (double pilot)Bistable (memory): pilot 14 switches 1→4, pilot 12 switches 1→2.
One-way flow control valveGRLA: throttles flow 2→1, free flow 1→2
Shuttle valve (OR)Outlet 2 receives the higher of the two inlet 1 pressures.
Two pressure valve (AND)Outlet 2 is pressurised only when both inlets 1 are.
Quick exhaust valveVents the cylinder chamber straight to atmosphere for a faster return stroke.
Time delay valve, normally closed (NC)3/2 NC with pilot 12 through a throttle and reservoir: switches after the set delay.
Pressure sequence valveSwitches 1→2 when pilot 12 reaches the set pressure.
Pressure gaugeShows line pressure (0–10 bar)
CompressorCompact didactic compressor with receiver, pressure switch and outlet coupling
Air pressure reservoirCompressed-air reservoir 0.4 L with two connections
Air filterFilter cartridge 40 µm in a transparent bowl
Filter with manual drainFilter with condensate drain screw at the bottom of the bowl
Filter with automatic drainFilter with float-operated condensate drain
Water separator, manual drainCentrifugal water separator with manual drain
Water separator, automatic drainCentrifugal water separator with automatic drain
LubricatorOil mist lubricator with sight dome
CoolerAir aftercooler (heat exchanger)
Air dryerMembrane air dryer
Pressure regulator with gaugeRelieving pressure regulator (LR) with gauge: keeps port 2 at the set pressure and vents any excess.
Single-acting cylinder, spring extendedPull-type cylinder: the spring keeps the rod extended, air on port 2 retracts it.
Cylinder with two-sided piston rodDouble-acting cylinder with through rod: equal force and speed in both directions.
Double-acting cylinder with guide unitCylinder with guide rods and yoke plate (anti-rotation, takes side loads).
Multiple position cylinderTwo cylinders (40 mm and 60 mm) coupled back to back: positions 0, 40, 60 and 100 mm
Linear drive (rodless)Slotted rodless cylinder DGC with magnetic piston: the carriage runs along the profile
Semi-rotary actuatorRotary vane drive DSM, 0–180°
Air motorVane air motor, reversible: air through 1→2 turns it one way, 2→1 the other way.
Vacuum suction nozzle (ejector)Venturi nozzle: compressed air on 1 creates vacuum on port V (up to −0.85 bar)
Suction cupBellows suction cup with workpiece
Distance ruleScale in mm placed along a cylinder to mark switching positions of limit valves and sensors (no connections).
3/2-way valve with push button, normally open (NO)Normally open: 1→2 at rest, push button closes 1 and exhausts 2.
3/2-way valve with mushroom actuator (emergency)Red mushroom on a yellow housing (pneumatic emergency stop)
3/2-way roller lever valve, normally open (NO)Normally open limit valve: the cam closes it.
3/2-way idle return roller valveOne-way roller (idle return): actuated only while the cam travels towards the end position the valve is mounted at, giving a short pulse; the other way the lever folds away
3/2-way valve, pneumatic, normally open (NO)Normally open, closes when pilot 10 is pressurised.
5/3-way pneumatic valve, closed centreSpring centred
Low pressure amplifierPilot 12 switches at only 0.15 bar: amplifies weak signals (e.g
Pneumatic proximity switchMagnetically actuated 3/2 valve clipped onto the cylinder: 1→2 while the piston magnet is underneath.
Pressurizing valve (soft start)Fills the downstream system slowly through a throttle; opens fully once 50 % of the inlet pressure is reached
Time delay valve, normally open (NO)3/2 NO with throttle and reservoir on pilot 10: closes 1→2 after the set delay.
NozzleBlow-off nozzle: vents to atmosphere through a fixed jet.
Throttle valveAdjustable needle valve, throttles in both directions (also: variable orifice).
OrificeFixed restrictor fitting Ø 0.5 mm.
Check valveNon-return valve: free flow 1→2, blocked 2→1.
Spring loaded check valveOpens 1→2 above 0.5 bar cracking pressure.
Check valve, piloted to openFree flow 1→2; pressure on pilot 21 also opens 2→1.
Spring loaded check valve, piloted to openOpens 1→2 above 0.5 bar; pilot 21 releases 2→1.
Pilot to close check valveFree flow 1→2 unless pilot 21 is pressurised.
Pilot to close check valve, spring loadedOpens 1→2 above 0.5 bar unless pilot 21 is pressurised.
Pneumatic counterPreset counter: counts pressure pulses on 12; output 1→2 switches at the preset; pressure on 10 resets.
Pressure relief valveVents port 1 to atmosphere when the pressure exceeds the setting (adjustable).
Closing pressure valve (2/2-way, normally open)Passes 1↔2 until the pressure at 2 reaches the setting, then closes (adjustable).
Opening pressure valve (2/2-way, normally closed)Opens 1→2 once the pressure at 1 reaches the setting (adjustable).
Stepper module (TAA)Sequence step (TAA)
Stepper module with initial step (TAB)Initial step (TAB): set by the reset signal L
Two-hand control blockOutput 1→2 only if both inputs 11 and 12 are pressurised within 0.5 s of each other; both must be released before the next cycle.
QuickstepperPneumatic sequencer: S starts step 1 (output A1); each step k advances when its condition Xk is pressurised; after step 6 it returns to idle
Differential pressure gaugeShows p1 − p2 (−5…+5 bar).
Pressure indicatorOptical indicator: the disc turns green above 1 bar.
Flow meterVariable-area flow meter (float in a glass tube) with digital read-out, 0–100 L/min.
Ring sensorPneumatic ring sensor: low-pressure supply on 1; output 2 is pressurised while the rod passes through the ring

Electropneumatics

ComponentFunction
3/2-way solenoid valve, normally closed (NC)Single solenoid Y1, spring return
5/2-way solenoid valveMonostable: Y1 switches 1→4; spring returns 1→2
5/2-way solenoid impulse valveBistable: Y1 switches 1→4, Y2 switches 1→2
5/3-way solenoid valve, closed centreSpring centred
Valve terminal with 4 solenoid valves (VMPA)2× 5/2 monostable (533342, air-spring return) + 2× 5/2 bistable (533343), servo-piloted with manual override: they need at least 1.5 bar at 1 to switch
Electrical limit switch (roller)Changeover contact: 1 common, 2 NC, 4 NO
Magnetic proximity switchSMT-8 3-wire PNP: BN +24 V, BU 0 V, BK output
Pressure switchPneumatic-electric converter: contact 1–4 closes when the pressure at P exceeds the setting.
3/2-way solenoid valve, normally open (NO)Normally open, coil Y1 closes it.
5/3-way solenoid valve, exhausted centreSpring centred, centre position exhausts 2 and 4 (cylinder can be pushed by hand).
5/3-way solenoid valve, pressurized centreSpring centred, centre position pressurises 2 and 4.
Proportional directional valve 5/3MPYE: setpoint U 0–10 V
Proportional pressure regulatorVPPE: outlet 2 follows the setpoint, 0–10 V → 0–10 bar (limited by the inlet)
Analog flow sensorSFE flow sensor: 0–50 L/min → 0–10 V on OUT (24 V supply).
Pressure sensor (switching output)Electronic pressure switch, 3-wire PNP: BN +24 V, BU 0 V; output BK switches to 24 V when the pressure at P exceeds the setting.
Analog pressure sensorSPTE pressure sensor: 0–10 bar → 0–10 V on OUT (24 V supply).
Differential pressure switchContact 1–4 closes when p1 − p2 exceeds the setting.
Capacitive proximity switchSIEF-style capacitive sensor, detects any material at the rod-end cam
Inductive proximity switchInductive sensor M12, detects the metal rod-end cam
Optical proximity switchDiffuse optical sensor, detects the rod-end cam by reflected light

Electrical

ComponentFunction
Relay module, three-fold3 relays K1–K3 with 4 changeover contacts each (11 common, 12 NC, 14 NO)
Push-button module (signal input)S1 detented, S2–S4 momentary (13/14 NO, 21/22 NC); 4 indicator lamps H1–H4
Power supply unit, 24 V DCShort-circuit-proof 24 V DC supply, max
Time relay, two-foldTwo-fold time relay (compatible with the didactic two-fold time relay 162243): K1T pick-up (on) delay, K2T release (off) delay, each 0.5–10 s set with the potentiometer knob
Preset counter, electronicElectronic preset counter (compatible with the didactic preset counter 1677856): counts 24 V pulses on A1/A2 (max
Emergency stopLatching mushroom button: click to press, click again to release (twist)
Direct current motor, 24 V (DC motor)Permanent-magnet DC motor; speed follows the applied voltage, direction follows polarity.
VoltmeterDigital voltmeter: shows the voltage between + and COM.
Ammeter (ampere meter)Digital ammeter, wired in series
Buzzer24 V signal buzzer (sound plays after your first click on the page).
Function generatorSignal source 0–10 V: square, sine or triangle with adjustable frequency, amplitude and offset (24 V supply).
Setpoint value cardFour setpoints W1–W4 (0–10 V)
Displacement encoderLinear potentiometer coupled to the cylinder alongside it: 0–10 V on OUT proportional to the rod position (24 V supply).
Indicator and distributor plateTP201 module: +24 V and 0 V distribution rails and two indicator lamps H1/H2 (layout simplified).
Proportional amplifier, one channelAmplifier card for proportional solenoids: input W 0–10 V → output U to the valve.
Proportional amplifier, two channelsAmplifier card for proportional solenoids: input W 0–10 V → output U to the valve (channel B mirrors W around 5 V for two-solenoid valves).

Hydraulics

ComponentFunction
Hydraulic power unitPower unit with a vertical clear oil reservoir: gear pump with motor (2 L/min), relief valve, gauge, P supply and T return couplings
Double-acting hydraulic cylinderØ16/10 mm, 200 mm stroke
4/3-way hand lever valve, closed centreClosed centre, detented
4/3-way solenoid valve, closed centreSpring centred
4/2-way solenoid valveSingle solenoid Y1 (P→A), spring return (P→B).
Check valve (hydraulic)Free flow from A to B; blocks from B to A.
One-way flow control valve (hydraulic)Throttles A→B; free return B→A through the check valve.
Pressure relief valve (hydraulic)Opens P→T when the pressure exceeds the setting.
Distributor blockDistributor with 4 self-sealing quick couplings.
Distributor block (6 couplings)Distributor with 6 self-sealing quick couplings.
Distributor block (8 couplings)Distributor with 8 self-sealing quick couplings.
Hydraulic pressure gaugeShows pressure (0–100 bar).
Hydraulic motorBidirectional gear motor: turns with the flow A→B or B→A.
Hydraulic pump with motorGear pump driven by an electric motor: draws oil from S (connect to the tank) and delivers it on P
TankOil tank / tank return block: port T is at atmospheric pressure.
Hydraulic accumulatorDiaphragm accumulator 0.16 L, nitrogen precharge adjustable
Hose with quick couplingsExtension hose with self-sealing couplings on both ends (on the bench every connection is such a hose).
HeaterOil heater in the return line (temperature is not simulated; it passes flow).
Single-acting hydraulic cylinderPlunger cylinder Ø16 mm, 200 mm stroke: A extends, the load/spring retracts.
Hydraulic cylinder with two-sided piston rodDouble-acting, through rod: equal areas and speeds in both directions.
Semi-rotary actuator (hydraulic)Rotary actuator 0–180°: A turns clockwise, B back.
3/2-way hand lever valve3/2-way hand lever valve
4/2-way hand lever valve (P→B at rest)4/2-way hand lever valve (P→B at rest)
4/2-way hand lever valve (P→A at rest)4/2-way hand lever valve (P→A at rest)
4/3-way hand lever valve, tandem centre (bypass position P→T)4/3-way hand lever valve, tandem centre (bypass position P→T)
4/3-way hand lever valve, open centre4/3-way hand lever valve, open centre
4/3-way hand lever valve, float centre (A,B→T)4/3-way hand lever valve, float centre (A,B→T)
4/3-way hand lever valve, P→A,B centre4/3-way hand lever valve, P→A,B centre
4/3-way hand lever valve, A→T centre4/3-way hand lever valve, A→T centre
2/2-way stem actuated valve, normally closed (NC)2/2-way stem actuated valve, normally closed (NC)
2/2-way stem actuated valve, normally open (NO)2/2-way stem actuated valve, normally open (NO)
4/2-way solenoid valve (P→A at rest)4/2-way solenoid valve (P→A at rest)
4/3-way solenoid valve with bypass position4/3-way solenoid valve with bypass position
4/3-way solenoid valve, open centre4/3-way solenoid valve, open centre
4/3-way solenoid valve, float centre4/3-way solenoid valve, float centre
4/3-way solenoid valve, P→A,B centre4/3-way solenoid valve, P→A,B centre
4/3-way solenoid valve, A→T centre4/3-way solenoid valve, A→T centre
Orifice / nozzle (hydraulic)Fixed restrictor Ø 0.8 mm.
Throttle valve (hydraulic)Adjustable needle valve, throttles both directions.
Shutoff valveBall valve: click to open/close.
Check valve, spring loaded (hydraulic)Opens A→B above 1 bar.
Check valve, piloted to open (hydraulic)Free flow A→B; pressure on X also opens B→A (load holding).
Spring loaded check valve, piloted to open (hydraulic)Opens A→B above 1 bar; pilot X releases B→A.
Pilot to close check valve (hydraulic)Free flow A→B unless X is pressurised.
Pilot to close check valve, spring loaded (hydraulic)Opens A→B above 1 bar unless X is pressurised.
2-way flow control valvePressure-compensated: keeps the set flow A→B independent of the load; free return B→A via check valve.
3-way flow control valvePressure-compensated with bypass: A receives the set flow, surplus flow returns via T at load pressure + 5 bar.
Shuttle valve (hydraulic)Outlet A receives the higher of the two inlet pressures.
Two pressure valve (hydraulic)Outlet A receives the lower of the two inlet pressures (AND).
Flow dividerSplits the inlet flow P into two equal flows A and B (synchronises two actuators).
Pressure reducing valveKeeps the outlet A at the set pressure; closes when it is reached.
3-way pressure reducing valveKeeps A at the set pressure in both directions: feeds from P, relieves to T.
Shutoff / counterbalance valveOpens A→B only above the set pressure (holds a load); free return B→A via the check valve.
Closing pressure valve (hydraulic)Passes A↔B until the pressure at B reaches the setting.
Opening pressure valve (hydraulic)Opens A→B once the pressure at A reaches the setting (sequence valve).
Opening cartridge valve2-way cartridge: opens A→B when A exceeds the control pressure X by 2 bar.
Closing cartridge valve2-way cartridge: open A↔B, closed while the control port X is pressurised.
4/3-way proportional valveSetpoint U 0–10 V: 5 V centre closed, 10 V P→A / B→T fully open, 0 V P→B / A→T
Proportional throttle valveOpening A↔B proportional to the setpoint U (0–10 V)
Proportional pressure relief valveOpening pressure follows the setpoint: 0–10 V → 0–60 bar
Proportional pressure reducing valveOutlet A follows the setpoint: 0–10 V → 0–60 bar (limited by P)
Differential pressure gauge (hydraulic)Shows p1 − p2 (−50…+50 bar).
Pressure indicator (hydraulic)Optical indicator: the disc turns green above 5 bar.
Flow meter (hydraulic)Gear-type flow meter with read-out, 0–5 L/min.
Analog flow sensor (hydraulic)0–5 L/min → 0–10 V on OUT (24 V supply).
Analog pressure sensor (hydraulic)0–100 bar → 0–10 V on OUT (24 V supply).
Pressure switch (hydraulic)Contact 1–4 closes when the pressure at P exceeds the setting.