Open the 3D workbench

Structures and strength of materials

Beam deflection and structures experiments on a 3D test frame

Clamp a steel, aluminium or timber specimen in the frame, add fixed, pinned, roller or spring supports and internal hinges, hang the weights and read the dial gauges, inclinometers and load cells — then compare the measurements with the shear force, bending moment and deflection diagrams.

Beam Deflection Simulator — Structures Lab in 3D

What you can study

Beam theory

Simply supported beams, cantilevers, superposition, the effect of the second moment of area (flat or on edge) and of the modulus of elasticity.

Statically indeterminate structures

Propped cantilevers, continuous beams and Gerber beams with internal hinges, solved with compatibility of displacements.

Instruments

Dial gauges (0.01 mm), digital inclinometers (0.01°), load cells (0.1 N) and strain gauges, zeroed before loading as in a real laboratory.

Diagrams

Structural model, deflected shape, shear force and bending moment, at true scale or exaggerated, linked to the 3D frame.

Steel beam design

Design an IPE beam (EN 10365 sections) to EN 1993-1-1 with the same structural model: ULS combination 1.35 G + 1.5 Q (EN 1990, 6.10), bending, shear and the deflection limit.

Lateral-torsional buckling

The elastic critical moment Mcr is checked for slender sections, so a flat bar on edge can fail by buckling before it yields.

Equipment (11 items)

Specimen

Supports and connections

Loads

Instruments

10 graded challenges

Each challenge checks the set-up, the zeroing of the instruments and the measured values against theory.

Example set-ups

Simply supported beam · Cantilever with inclinometer · Reactions with load cells · Continuous beam (statically indeterminate) · Gerber beam with hinge

Structures lab in VisoTrain: 3D test frame with a loaded beam and the bending moment and deflection diagrams
Structures lab in VisoTrain: 3D test frame with a loaded beam and the bending moment and deflection diagrams

Frequently asked questions

Which beam cases are included?

Simply supported beams, cantilevers, propped cantilevers, two-span continuous beams and Gerber beams with hinges, with point loads, weight hangers and distributed loads.

Does it follow the Eurocodes?

The design tool uses EN 1990 load combinations and EN 1993-1-1 resistance checks for IPE steel sections to EN 10365.

Can I compare measurements with theory?

Yes. The instruments read the simulated deflections, rotations and reactions, and the diagrams show the theoretical values for the same model.

Build your first circuit in two minutes — free, in the browser.Open the 3D workbenchPlans and pricing